Fanuc master board alarm codes 10/11 controls
Fanuc System 10 and series Fanuc 11 master board alarm codes
FANUC 10/11 MASTERBOARD ALARMS

Display: A.
Description: MDI Connection Failure.
Repair: Check fiber optic cable connection between control and MDI/CRT unit.

Display: C.
Description: MDI Failure.
Repair: Check the type (9", 14", etc.) of CRT/MDI unit or the edition number of NC software.
Connecting unit for operators panel or connecting cable is defective.

Display: F.
Description: Connection failure of connection unit or I/O cards D1-D3
Repair: Check fiber optic cable connections between units.
Replace Master PCB, Connection unit, I/O Board, Fiber Optic Cable
Failed I/O module in I/O base unit.

Display: H.
Description: Connection failure I/O.
Repair: Connection unit 2 or its connecting cable defective.

Display: c.
Description: Transfer error through fiber optic cable.
Repair: Check front panel power supply.
Replace Master PCB, MDI PCB, Connection unit PCB, I/O Unit, Fiber Optic cable.

Display: J.
Description: PC or interface converter not functioning.
Repair: Check PC-ROM cassette, PC Ram board, or interface convertor is mounted on Master PCB.

Display: L.
Description: Waiting for PC ready.
Repair: Replace PC ROM, PC ROM cassette or PC RAM Board.
Check PMC program.

Display: b.
Description: RAM check error.
Repair: Replace Master or ROM/RAM board.

Display 8.
Description: RAM check
Repair: Check power supply, Clear memory and reload parameters, Replace Master Board

Display: d.
Description: Power supply ready signal
Repair: Replace power supply, Master PCB

Display: E.
Description: System Error
Repair: Replace Master PCB , ROM PCB, or NC Software ROM
Wrong option parameters
No message on CRT – Clear Memory

Display: O.
Description: IPL MODE

Display: 1
Description: Normal Operation

Display: 4.
Description: Bad ACP
Repair: Replace ACP daughter board.

Display: Others
Description: System Error.
Repair: Replace master PCB, NC Software, ROM or ROM PCB

Fanuc - Fanuc Help - Fanuc Control Spares

Fanuc Master Board Alarm Codes PDF Fanuc Master Board Alarm Codes PDF


Search Site


Pennine Automation Spares
Brookwoods Industrial Estate
Holywell Green Halifax
West Yorkshire
HX4 9BH England uk
sales@pennineuk.com

Com Reg No 6913788
VAT No GB 973599456
Tel:+44 (0) 1422 370109
Fax:+44 (0) 1422 371338
email:click here

© 2012 Copyright Pennine Machine Tools Ltd. All rights reserved